BOFA Laser Smoke Extraction Base Unit – AD Base 1 Oracle
The Donaldson BOFA AD Base 1 Oracle is a ride-on fume extractor for laser engraving. The laser machine sits on top of the extractor, so...
Supplied in India by United Spectrum Instruments, an authorised Donaldson BOFA distributor.BOFA Laser Smoke Extraction Base Unit – AD Base 1 Oracle
Laser Extraction for Laser Marking and Coding Systems : AD Base 1 Oracle
The Donaldson BOFA AD Base 1 Oracle is a ride-on fume extractor for laser engraving. The laser machine sits on top of the extractor, so the unit also works as a workstation. It moves 380 m³/h of air at 96 mbar and runs below 64 dB(A). A DeepPleat DUO pre-filter (ePM1 70%) catches larger particles. A combined filter then removes fine particles with a HEPA stage (99.995% at 0.3 microns) and gases with 15.5 litres of activated carbon. It measures 790 × 735 × 740 mm, weighs 86 kg and runs on 115–230 V. It carries UKCA and CE approval.
United Spectrum Instruments is the official BOFA distributor in India. We supply, install and service the AD Base 1 Oracle across the country.
Understanding AD Base 1 Oracle
The AD Base 1 Oracle combines a sturdy machine base with efficient fume extraction. Your laser sits on top, which saves floor space. Its filters remove harmful particles, fumes and gases from laser engraving, marking and cutting. It runs quietly and reliably. It protects operators and laser equipment in one practical unit.
Technical Specifications
| Model | Donaldson BOFA AD Base 1 Oracle (Advantage Range) |
| Format | Ride-on system: the laser sits on top, so the unit doubles as a workstation |
| Airflow | 380 m³/h (224 cfm) |
| Pressure | 96 mbar (±10%) |
| Voltage / frequency | 115–230 V, 50/60 Hz, single phase |
| Full load current | 12.5 A |
| Noise level | < 64 dB(A) at typical operating speed |
| Dimensions (H × W × D) | 790 × 735 × 740 mm |
| Weight | 86 kg (±5%) |
| Hose inlet | 75 mm (2.9″) |
| Pre-filter | DeepPleat DUO, 12 m² media, ePM1 70%, part no. 1UA1030156 |
| Combined filter | HEPA 99.995% at 0.3 microns (4.6 m² media) + 15.5 litres activated carbon, part no. 1UA1030155 |
| Cabinet | Powder-coated mild steel (RAL7016), on castors |
| Options | Remote stop/start (S/S), System OK signal (SOK), override (O/R), VOC sensor, onboard compressor (COMP) |
| Approvals | UKCA, CE |
Key Features and Advantages
Dual Functionality
Functions as both a laser machine base and a fume extraction unit, reducing the need for additional equipment.
Advanced Multi-Stage Filtration
Utilises pre-filters, HEPA filters, and chemical filters to effectively capture dust, fumes, and gases.
Status Monitoring
A clear control panel shows system status. Optional System OK (SOK) and VOC sensor signals can alert you to problems.
Ride-On, Space-Saving Design
Perfect for small-to-medium laser systems, maximising floor space in workshops and production facilities.
Quiet Operation
Provides powerful extraction while keeping noise levels low for operator comfort.
Equipment Protection
Prevents dust and corrosive fumes from damaging sensitive laser components, extending equipment life.
Safety and Compliance
Ensures compliance with occupational health and safety standards by maintaining clean, breathable air.
Easy Maintenance
Automatic filter change alerts and quick-access panels simplify servicing, reducing maintenance time.
Energy Efficiency
Delivers strong performance while optimising energy use, making it cost-effective for continuous operation.
The AD Base 1 Oracle saves space, lasts well and extracts fumes reliably. It is an excellent choice for businesses using laser engraving and marking machines.
Applications Across Industries
Laser Engraving and Marking
It suits engraving and marking machines that work on plastics, wood, composites and metals. It captures fumes and particles efficiently.
Jewellery and Watchmaking
It removes fine dust and fumes from engraving and polishing precious metals. This protects both equipment and craftspeople.
Automotive and Aerospace
It supports laser marking and part engraving. It removes fumes from plastics, alloys and light composites.
Electronics and PCB Manufacturing
It captures fumes from laser marking of PCBs, connectors and components. This protects operators and product quality.
Medical Devices
It filters harmful emissions during the production of precision instruments and implants. This helps keep production areas clean.
Research and Education
Universities, technical institutes and R&D labs use it for safe, reliable extraction during laser training and experiments.
Packaging and Printing
It gives safe extraction when marking and coding packaging, including plastics and coated materials.
General Manufacturing
It suits a wide range of laser jobs, from industrial marking to decorative engraving. It keeps air quality stable and safe.
It combines a stable machine base with efficient extraction. It delivers safety, space savings and reliable performance across industries.
Why Choose United Spectrum Instruments?
Why Choose United Spectrum Instruments? (80 words)
United Spectrum Instruments supplies Donaldson BOFA extraction systems in India, with expert local support.
Authorised distributor of BOFA systems.
Skilled in integrating ride-on extraction with laser engraving machines.
Nationwide service, installation, and after-sales support.
Trusted solutions for industrial, medical, and research applications.
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What type of lasers is the AD Base 1 Oracle compatible with?
It works with CO₂, fibre, UV, and diode lasers used in marking, coding, and light-duty engraving applications.
Can the AD Base 1 Oracle be used with enclosed laser workstations?
Yes. It is designed to be installed beneath benchtop or enclosed laser marking units for seamless integration.
Does the AD Base 1 Oracle support data logging?
No built-in data logging is listed for this model. It offers optional remote stop/start, System OK (SOK) and VOC sensor signals. For live data and connectivity, consider the AD Oracle Pro OS Connect.
Is this suitable for cleanroom environments?
It uses a pre-filter, a HEPA filter rated 99.995% at 0.3 microns and activated carbon for gases. Whether it suits a cleanroom depends on your process and room class. Contact us and we will check your application.
What is the maintenance requirement for this system?
Maintenance is simple. Open the front door to change the pre-filter (1UA1030156) and the combined filter (1UA1030155).