Opens in a new tab

Gallium Phosphide (GaP) Photodetector – TOCON_GAP9

The TOCON_GAP9 from SGLUX GmbH is a high-precision Gallium Phosphide (GaP) photodetector designed for visible and near-UV...

Home>
Explore Our Catalog
Download the full United Spectrum catalogue covering laser systems, fume extractors, optical sensors and photonics instruments from leading German manufacturers.
DOWNLOAD NOW!

Gallium Phosphide (GaP) Photodetector – TOCON_GAP9

1024x640
48 Galliumphosphide (GaP) Photodetector TOCON GAP9
43A Galliumphosphide (GaP) Photodetector Graph

TOCON_GAP9 – Gallium Phosphide Photodetector for Precision Visible and Near-UV Light Measurement Applications

The TOCON_GAP9 from SGLUX GmbH is a high-precision Gallium Phosphide (GaP) photodetector designed for visible and near-UV light measurement with superior spectral selectivity.
It integrates a solar-blind GaP photodiode and a low-noise transimpedance amplifier within a rugged TOCON housing, producing a 0–5 V DC output linear to incident irradiance.
With a spectral sensitivity range from 150 nm to 550 nm and peak response near 440 nm, it is ideal for UV-A, violet, and blue light detection.
Each sensor is factory-calibrated and traceable to NIST / PTB standards, ensuring high accuracy, reproducibility, and long-term stability.
The TOCON_GAP9 is widely used in LED testing, fluorescence analysis, optical instrumentation, and UV curing control, offering robust performance for both industrial and scientific applications.

The TOCON_GAP9 uses a Gallium Phosphide (GaP) photodiode known for its visible and near-UV light sensitivity while being insensitive to infrared radiation.
This property ensures precise detection of blue and UV-A radiation without unwanted IR interference.
The built-in low-noise amplifier provides a 0–5 V analog output, simplifying integration with PLCs, data acquisition systems, or the SGLUX SENSOR MONITOR 5.0.
Factory-calibrated to NIST / PTB standards, the TOCON_GAP9 ensures traceable, repeatable performance in LED photometry, process control, and fluorescence measurement where blue-region precision is essential.

Feature Specification
Function
Gallium Phosphide (GaP) photodetector with integrated amplifier
Detector Type
GaP photodiode with internal transimpedance amplifier
Spectral Range
150 – 550 nm (visible and near-UV)
Peak Wavelength 440 nm
Output Signal
0 – 5 V DC (linear with irradiance)
Sensitivity
High for blue and near-UV light
Accuracy ±5 % of reading
Response Time < 1 s
Visible / IR Rejection
Excellent IR blindness
Operating Voltage 5 – 24 V DC
Operating Temperature −20 … +85 °C
Housing Material
Anodised aluminium TOCON enclosure
Optical Window
UV-grade quartz or optical glass
Connector
BNC / M8 / custom cable output
Calibration
Factory-calibrated, traceable to NIST / PTB
Compatibility
SENSOR MONITOR 5.0 / VOLTCON / SGCD4 systems
Applications
Blue/UV-A light measurement, fluorescence detection, LED testing, optical instrumentation, UV curing control

Wide Spectral Sensitivity (150–550 nm)

The TOCON_GAP9 covers both near-UV and visible blue wavelengths, providing precise measurements in the transition region where standard Si or SiC detectors are less effective.

Infrared Blindness for True UV/Visible Detection

Its GaP detector ensures strong rejection of IR and red light, enabling pure spectral accuracy for UV-A and blue-light sources.

Factory-Calibrated Accuracy

Each unit is NIST / PTB traceable, ensuring reproducible, validated results suitable for scientific, industrial, and regulatory use.

Integrated Low-Noise Amplifier

The built-in transimpedance amplifier outputs a linear 0–5 V signal, eliminating the need for external circuitry or gain adjustment.

Fast Response and Low Drift

The solid-state GaP detector offers sub-second response with excellent signal stability over temperature and time.

Compact and Durable Construction

Encased in a robust anodised aluminium TOCON housing, providing resistance to mechanical and environmental stress.

Flexible Integration

Easily connects to SGLUX SENSOR MONITOR 5.0, VOLTCON, or SGCD4 controllers for real-time readout or data logging.

The TOCON_GAP9 offers outstanding spectral precision, traceable calibration, and fast output, making it the sensor of choice for blue-light metrology, UV-A testing, and optical process validation.

LED and Laser Testing

Used for output characterisation of UV-A and blue LEDs, ensuring consistent optical power and colour rendering.

Fluorescence and Photoluminescence Measurement

Monitors excitation light in fluorescence spectroscopy and optical bioassay systems.

Optical Instrumentation and Calibration

Acts as a reference detector in photometric and radiometric calibration setups.

UV Curing and Process Monitoring

Measures blue/UV-A irradiance in curing systems for adhesives, coatings, and inks.

Scientific and Laboratory Research

Supports spectral analysis, photobiology, and material testing in visible/UV regions.

Environmental and Lighting Studies

Evaluates daylight or artificial blue-light exposure in lighting research and safety compliance testing.

With its IR-blind GaP sensor, traceable calibration, and robust design, the TOCON_GAP9 ensures accurate and repeatable measurements for industrial, research, and optical engineering applications.

  • Exclusive distributor of SGLUX TOCON_GAP9 in India

  • Expertise in visible and near-UV light metrology systems

  • Local calibration traceable to NIST / PTB standards

  • Competitive solutions for LED testing, photometry, and fluorescence research

  • Pan-India integration, calibration, and technical support

FAQs

It uses a Gallium Phosphide (GaP) detector, sensitive to blue and UV-A light but blind to IR.

It measures from 150 nm to 550 nm, peaking near 440 nm.

Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.

Yes – ideal for UV-A and blue LED power measurement and calibration.

Through system integration, calibration, and nationwide service for optical and radiometric applications.

GET IN TOUCH WITH US

Have a Project in Mind ? Let’s Talk

Tell us about your project or requirements. Our business team will review your inquiry and contact you at the earliest.

FAQs

It uses a Gallium Phosphide (GaP) detector, sensitive to blue and UV-A light but blind to IR.

It measures from 150 nm to 550 nm, peaking near 440 nm.

Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.

Yes – ideal for UV-A and blue LED power measurement and calibration.

Through system integration, calibration, and nationwide service for optical and radiometric applications.

WHAT WE OFFER

Reliable Engineering Solutions for Modern Manufacturing

Delivering cutting-edge technologies and precision systems that enhance productivity, quality, and innovation in today’s manufacturing environments.
Icon8

Imaging Cameras & Wavefront Sensors

Imaging Cameras & Wavefront Sensors provide high-precision visual and measurement data for inspection, alignment, and process monitoring in industrial and scientific applications.
Discover More
Icon7

Laser Sources

Industrial and Scientific Laser Sources deliver stable, high-precision laser output for micro-machining, cutting, processing, research, and advanced scientific applications across diverse industrial environments
Discover More
Icon7

Dust & Fume Extractors

A Dust & Fume Extractor removes dust, smoke, and fumes at the source to maintain a clean and safe industrial workspace, ensuring regulatory compliance and operator health
Discover More
Icon6

Industrial Laser Systems

Industrial Laser Systems delivers high-precision, reliable laser performance for marking, cutting, welding, micro-machining, and advanced manufacturing applications across diverse industrial.
Discover More
Icon9

Optical Communication Test & Measurement

Optical Communication Systems integrate optical transmitters, receivers, lasers, and OSA for signal generation, transmission.
Discover More
Icon8

Optical Sensors, IR Emitters & LED's

Optical UV Sensors, IR Emitters and LED's provide precise ultraviolet detection and measurement for monitoring, analysis, safety, and scientific applications across industrial and research environments.
Discover More
Icon6

Opto-Electronic Packaging Systems

Opto-electronic packaging systems enable precise assembly, alignment, and packaging of opto-electronic devices for production.
Discover More