LED SMD OCI-460 ID1300
The OCI-460 ID1300 operates in the SWIR region at approximately 1300 nm, enabling deeper material penetration and enhanced interaction compared to visible and NIR wavelengths. It is part of the OCI-460 SWIR LED family, which includes wavelengths such as 1040 nm, 1200 nm, and 1300 nm for sensing applications. Operating at 1300 nm, the LED enables deeper penetration into materials compared to visible and NIR wavelengths. This makes it highly effective for spectroscopy, moisture detection, and material analysis. The OCI-460 ID1300 delivers strong radiant output, ensuring high signal intensity in sensing systems. This improves detection accuracy in applications such as chemical analysis and industrial monitoring. The compact footprint allows seamless integration into high-density PCB layouts, sensor modules, and portable devices, supporting modern miniaturised system designs. The ceramic substrate provides excellent heat dissipation, enabling stable operation at high drive currents up to 1.5 A. This enhances performance consistency and extends operational life. The integrated glob-top lens improves light extraction efficiency and protects the LED chip from environmental stress, ensuring stable optical output. A broad emission angle ensures uniform light distribution across sensing areas, reducing alignment sensitivity and improving measurement consistency. Designed for harsh environments, the LED operates across a wide temperature range and offers long-term stability in industrial, medical, and outdoor applications. Available in SMD and starboard configurations, the LED supports rapid prototyping and easy integration into customised photonic systems. The 1300 nm SWIR wavelength is widely used in spectroscopy for identifying materials, analysing chemical composition, and performing non-destructive testing in industrial environments. SWIR LEDs are highly effective for detecting moisture, fat, and organic content in food products, improving quality control in food processing industries. The LED supports advanced sensing applications such as proximity detection, object recognition, and process monitoring in automated manufacturing systems. SWIR illumination enables wafer inspection and defect detection in semiconductor manufacturing, revealing features not visible under standard lighting. The LED is used in analytical and diagnostic equipment where deep infrared penetration and stable emission are required for accurate biological and chemical measurements. The OCI-460 ID1300 is ideal for laboratory research, spectroscopy setups, and experimental systems requiring stable SWIR light sources with repeatable performance. United Spectrum Instruments is a trusted partner for advanced photonics solutions in India. We provide expert consultation, product selection guidance, and integration support tailored to industrial and research applications. With strong technical expertise and responsive after-sales service, we ensure reliable sourcing and long-term performance of high-power SWIR LEDs like OCI-460 ID1300. Our focus on quality, service, and customer success helps you achieve efficient, high-performance optical sensing systems. It operates at approximately 1300 nm in the SWIR range. It offers deeper penetration and better interaction with materials, making it ideal for spectroscopy and analysis. It is widely used in spectroscopy, industrial sensing, moisture detection, and semiconductor inspection. It comes in a compact 3535 SMD package suitable for high-density PCB integration. Yes, it supports operation from -40°C to +85°C for industrial applications. It operates at approximately 1300 nm in the SWIR range. It offers deeper penetration and better interaction with materials, making it ideal for spectroscopy and analysis. It is widely used in spectroscopy, industrial sensing, moisture detection, and semiconductor inspection. It comes in a compact 3535 SMD package suitable for high-density PCB integration. Yes, it supports operation from -40°C to +85°C for industrial applications.LED SMD OCI-460 ID1300
High Power 1300nm SWIR SMD LED for Industrial Sensing and Spectroscopy Applications - OCI-460 ID1300
Understanding OCI-460 ID1300
The LED features a ceramic submount for efficient heat dissipation and a glob-top lens for improved light extraction. Its high-power output and wide emission angle make it ideal for spectroscopy, industrial sensing, and analytical systems requiring stable and repeatable optical performance.Technical Specifications
Parameter
Specification
Product
OCI-460 ID1300
Type
High Power SWIR SMD LED
Peak Wavelength
~1300 nm
Optical Output
High power SWIR emitter
Forward Voltage
~1.4 – 1.6 V
Forward Current
Up to ~1000–1500 mA
Viewing Angle
~120° – 135°
Spectral Width (FWHM)
~70–90 nm
Package
3535 SMD
Dimensions
~3.5 × 3.5 mm
Substrate
Ceramic
Operating Temperature
-40°C to +85°C
Compliance
RoHS & REACH compliant
Key Features and Advantages
SWIR Wavelength for Deep Material Penetration
High Optical Output for Reliable Detection
Compact 3535 SMD Package
Efficient Thermal Management
Silicone Glob Top for Enhanced Efficiency
Wide Viewing Angle for Uniform Illumination
Industrial-Grade Reliability
Flexible Integration & Customisation
Applications Across Industries
Spectroscopy & Material Analysis
Moisture Detection & Food Inspection
Industrial Automation & Optical Sensors
Semiconductor & Wafer Inspection
Medical & Life Science Instrumentation
Research & Scientific Applications
Why Choose United Spectrum Instruments?
FAQs
What is the wavelength of OCI-460 ID1300?
What makes 1300 nm useful in sensing applications?
What applications is it best suited for?
What is the package type?
Can it operate in harsh environments?
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
What is the wavelength of OCI-460 ID1300?
What makes 1300 nm useful in sensing applications?
What applications is it best suited for?
What is the package type?
Can it operate in harsh environments?
WHAT WE OFFER
Reliable Engineering Solutions for Modern Manufacturing