Optical Component Analyser with OFDR in India

An optical component analyser sweeps a tunable laser across a passive optical device and records how its insertion loss (IL), return loss (RL) and polarisation-dependent...

Optical Component Analyser with OFDR in India

1024x640
HDCA optical component analyser with OFDR by Zepren in India
Zepren HDCA high definition component analyser front panel
HDCA 4-channel insertion loss measurement of bandpass filters
HDCA 2-channel analysis of a DQPSK 10 GHz device
HDCA insertion loss and PDL measurement of an adjusted bandpass filter
HDCA insertion loss and PDL measurement of an etalon filter
HDCA insertion loss and return loss filter characterisation

Femtometre-Resolution IL, RL and PDL Testing with OFDR Reflectometry for PICs, Ring Resonators, AWGs and FBGs — HDCA by Zepren

An optical component analyser sweeps a tunable laser across a passive optical device and records how its insertion loss (IL), return loss (RL) and polarisation-dependent loss (PDL) change with wavelength. It is the core instrument for qualifying filters, gratings, resonators and photonic integrated circuits (PICs).

The HDCA (High Definition Component Analyser) from Zepren Solutions, Spain, characterises passive devices with femtometre resolution (0.3 MHz / 2.4 fm minimum, 1 MHz typical), more than 85 dB of IL dynamic range at 100 nm/s and ±0.5 pm wavelength accuracy, in real time and fully automated. Beyond IL, RL and PDL it measures polarisation wavelength-dependent shift (PWDS), group delay and the optical time-domain response, and tests up to 4 channels at once, expandable with 6-port extension boxes. It is available in multiple bands from below 1 µm to the U-band and is compatible with external tunable lasers.

HDCA now includes OFDR (optical frequency domain reflectometry). With 6 µm sampling resolution, zero dead zone, −120 dB sensitivity and up to 147 m range in reflection mode, it locates reflections, discontinuities and propagation losses in fibre components, short optical links of around 250 m and even inside photonic integrated chips.

United Spectrum Instruments is the authorised sales partner of Zepren in India, providing application guidance, quotations, demonstrations, delivery and after-sales technical support to research institutions, academic laboratories and photonics manufacturers.

Spectral Analysis vs OFDR: What Each Mode Tells You

Spectral component analysisOFDR reflectometry
Question answeredHow do loss and delay change with wavelength?Where along the device or fibre does a reflection or loss occur?
MeasuresInsertion loss (IL), return loss (RL), polarisation-dependent loss (PDL) and polarisation wavelength-dependent shift (PWDS) spectra; TE/TM (transverse electric / transverse magnetic) spectra; group delaySpatial reflection profile, refractive index profile, defects, discontinuities, propagation loss
Key performance2.4 fm minimum resolution, >85 dB IL dynamic range, ±0.5 pm wavelength accuracy6 µm sampling resolution, zero dead zone, −120 dB sensitivity, up to 147 m reflection range
Typical useFilters, AWGs, WSS, FBGs, ring resonators, ultra-DWDM componentsFault finding in fibre components, short networks and inside PICs

One instrument, two views: HDCA lets you see both the spectral response and the physical location of faults on the same device, without moving it to a second test station. Contact United Spectrum Instruments, Chennai, for a quote or demo anywhere in India.

What is an optical component analyser?

It is a swept-laser test system that measures the insertion loss, return loss and polarisation-dependent loss of a passive optical device as a function of wavelength, giving a complete spectral picture of how the device behaves.

Why does femtometre resolution matter?

Devices such as high-Q ring resonators, narrow FBGs and ultra-dense DWDM filters have features far narrower than one picometre. HDCA resolves down to 0.3 MHz (2.4 fm), so resonance shapes, notch depths and ripple are measured accurately instead of being smoothed out.

What is OFDR and what does it add?

Optical frequency domain reflectometry converts the swept-laser measurement into a map of reflections versus distance. With 6 µm sampling resolution and zero dead zone, it shows where along a fibre, connector or waveguide a reflection, defect or loss occurs, which is ideal for troubleshooting components, short links and the inside of photonic chips.

Why measure group delay and time-domain response?

Measuring spectral and time-delay response together is key for devices such as fibre Bragg gratings: it reveals the refractive index profile, detects defects and gives the group delay, for example when qualifying dispersion compensators for communication links.

How are PDL and TE/TM spectra measured?

With the polarisation analysis option, HDCA measures PDL and the separate TE and TM spectral responses of wavelength-selective devices, giving the polarisation wavelength-dependent shift. For periodic or filtering devices, where conventional Mueller-based PDL analysis is not enough, an advanced method extracts the spectra along the principal states of polarisation.

Optical
Resolution0.3 MHz (0.0024 pm) minimum / 1 MHz typical
Number of channels1 included, up to 4 optional; additional channels on request (6-port extension boxes)
Calibrated input power range+10 to −90 dBm
Output power0 dBm (minimum)
Polarisation measurementTwo orthogonal polarisations; PDL and PWDS measurement as option
Sweep speed10, 20, 40 or 100 nm/s
Wavelength referenceLinearisation + absolute reference
Performance
Wavelength accuracy±0.5 pm (typical)
Dynamic range – IL>85 dB at 100 nm/s
Dynamic range – RL>55 dB
Power accuracy – IL±0.1 dB (typical)
Power accuracy – RL±0.5 dB (typical)
Power resolution0.001 dB
PDL accuracy±0.04 dB
PDL repeatability±0.02 dB
MeasurementsInsertion loss (IL), return loss (RL), polarisation-dependent loss (PDL), polarisation wavelength-dependent shift (PWDS), TE/TM (transverse electric / transverse magnetic) spectra, group delay (GD), optical time-domain response
OFDR option
Sampling resolution6 µm (S, C and L bands) / 7 µm (O-band)
Measurement range – reflection mode14 / 36 / 73 / 147 m*
Measurement range – transmission mode28 / 72 / 146 / 294 m*
Fibre length repeatability±50 µm
Sensitivity−120 dB
Available wavelength bands
<1 µm881–938 nm, 921–988 nm
T-band1011–1108 nm (T1: 1031–1068 nm, T2: 1071–1128 nm)
O-band1261–1348 nm
E-band1357–1478 nm
S+C+L1482–1628 nm
C+L1521–1628 nm
C-band1521–1565 nm
U-band1622–1748 nm
Interfaces
Remote controlGPIB or Ethernet, SCPI commands
ProgrammingLabVIEW, Python, MATLAB
External tunable laserCompatible (100 series)

* Group index ng = 1.48 at 1550 nm. Specifications are taken from the Zepren HDCA brochure. For full details for your band and configuration, contact United Spectrum Instruments.

Femtometre Resolution, Fully Automated

Resolution down to 0.3 MHz (2.4 fm) captures the true shape of narrow resonances, notches and ripple, in real time and without manual steps.

Over 85 dB Dynamic Range

IL dynamic range above 85 dB at 100 nm/s and RL above 55 dB let you measure deep stop-bands and high-isolation filters in one sweep.

Complete Set of Measurements

Insertion loss, return loss, PDL, polarisation wavelength-dependent shift, group delay and optical time-domain response from one instrument.

Multi-Channel Testing for Production

Up to 4 ports measure several channels simultaneously, and 6-port extension boxes add more ports to cut characterisation time on multi-port devices and PICs.

Built-In OFDR Reflectometry

6 µm sampling resolution, zero dead zone and −120 dB sensitivity locate reflections, defects and propagation losses in fibre components, short links and inside photonic chips.

Advanced Polarisation Analysis

Measure PDL (±0.04 dB accuracy) and separate TE and TM spectra, including an advanced method for periodic and filtering devices where Mueller-based PDL analysis falls short.

Multiple Wavelength Bands and External TLS Support

Available from below 1 µm through T, O, E, S, C, L and U bands, and compatible with external tunable lasers (100 series).

Automation and 24/7 Operation

Remote control over GPIB or Ethernet with SCPI commands, LabVIEW, Python and MATLAB support, and a design robust enough to run continuously for a week.

Silicon Photonics and PIC Characterisation

Inspect inside photonic integrated circuits with OFDR to find internal loss profiles and waveguide attenuation, and measure the spectral response of each device. Integrating OFDR into PIC test speeds up R&D and supports scaling silicon photonics to production.

Ring Resonators and High-Q Devices

Measure resonance linewidth, extinction and free spectral range of micro-ring and other high-Q resonators with femtometre resolution, a common need in IIT and IISc integrated photonics labs.

Fibre Bragg Gratings and Dispersion Compensators

Measure spectral and group-delay response together to analyse the refractive index profile, detect defects and qualify FBGs used for sensing and dispersion compensation.

AWG, WSS and Ultra-DWDM Components

Verify channel passbands, crosstalk and isolation of AWGs, wavelength selective switches and ultra-dense DWDM filters, testing several ports at once.

Quantum Photonic Chips

Characterise the passive building blocks of quantum photonic circuits, where low loss and precise resonance alignment are critical.

Short Fibre Link Troubleshooting

Find micro-bends, splices, connector faults and other fine-scale defects in short high-performance links of around 250 m, such as data-centre networks, fibre-to-the-premises (FTTP) installations and onboard networks in aircraft and ships.

Telecom and Optical Component Manufacturing

Automate multi-channel IL, RL and PDL testing of passive components in production with SCPI control. For laser and signal spectra, see also the BOSA high resolution optical spectrum analyser.

Authorised Zepren Sales Partner in India

United Spectrum Instruments is the authorised sales partner of Zepren Solutions in India, so you receive a genuine HDCA with manufacturer-backed calibration and support.

Help Configuring Bands, Channels and Options

We review the devices you test, their wavelengths, port counts and polarisation needs, and recommend the band, channel count, polarisation option and OFDR set-up that fits your work.

Experience with Indian Research and Industry

We work with IITs, IISc, CSIR laboratories, defence establishments and telecom companies, and understand academic and government procurement and documentation requirements.

Delivery and Local Technical Support

We deliver anywhere in India and support installation, software, SCPI automation and troubleshooting.

A Complete Optical Test Portfolio

Alongside HDCA we supply the BOSA high resolution optical spectrum analyser, the ID OSA compact optical spectrum analyser, tunable lasers and coherent test equipment, so your optical test bench can come from one partner.

GET IN TOUCH WITH US

Have a Project in Mind ? Let’s Talk

Tell us about your project or requirements. Our business team will review your inquiry and contact you at the earliest.

FAQs

The HDCA (High Definition Component Analyser) from Zepren Solutions, Spain, is a swept-laser optical component analyser that characterises passive optical devices and PICs with femtometre resolution, and now also includes OFDR reflectometry.

Optical frequency domain reflectometry is a technique that converts a swept-laser measurement into a map of reflections versus distance. It shows where reflections, defects and losses occur along a fibre or inside a device.

The HDCA resolves down to 0.3 MHz (0.0024 pm, or 2.4 fm) minimum, with 1 MHz typical.

IL dynamic range is above 85 dB at 100 nm/s and RL dynamic range above 55 dB, with a calibrated input power range of +10 to −90 dBm.

Wavelength accuracy is ±0.5 pm (typical), IL power accuracy ±0.1 dB, RL power accuracy ±0.5 dB, PDL accuracy ±0.04 dB and power resolution 0.001 dB.

Bands are available from below 1 µm (881–938 nm and 921–988 nm) through T, O, E, S, C, L and U (1622–1748 nm). The HDCA is also compatible with external tunable lasers (100 series).

Insertion loss, return loss, PDL, polarisation wavelength-dependent shift, TE and TM spectra, group delay and optical time-domain response, and with OFDR the spatial profile of reflections and losses along the device.

One channel is included and up to 4 are optional for simultaneous measurement. Extension boxes with up to 6 additional ports each can increase the port count further.

Sampling resolution is 6 µm in the S, C and L bands (7 µm in the O-band), measurement range up to 147 m in reflection or 294 m in transmission, fibre length repeatability ±50 µm and sensitivity −120 dB.

Yes. The OFDR function identifies internal loss profiles, reflections and discontinuities inside photonic integrated chips as well as in fibre components.

Ring resonators, AWGs, wavelength selective switches, fibre Bragg gratings, dispersion compensators, ultra-DWDM filters, photonic integrated circuits and quantum photonic chips, plus short fibre links of around 250 m.

United Spectrum Instruments, Chennai, is the authorised sales partner of Zepren in India and supplies the HDCA with application support, delivery and after-sales service.

Use the Get in Touch form on this page, email sales@unitedspectrum.in, or call +91 93631 83748 or +91 97899 04948. Tell us the devices you test, your wavelength band, channel count and polarisation needs, and we will send the datasheet and a quotation.

WHAT WE OFFER

Reliable Engineering Solutions for Modern Manufacturing

Delivering cutting-edge technologies and precision systems that enhance productivity, quality, and innovation in today’s manufacturing environments.
Icon8

Imaging Cameras & Wavefront Sensors

Imaging Cameras & Wavefront Sensors provide high-precision visual and measurement data for inspection, alignment, and process monitoring in industrial and scientific applications.
Discover More
Icon7

Laser Sources

Industrial and Scientific Laser Sources deliver stable, high-precision laser output for micro-machining, cutting, processing, research, and advanced scientific applications across diverse industrial environments
Discover More
Icon7

Dust & Fume Extractors

A Dust & Fume Extractor removes dust, smoke, and fumes at the source to maintain a clean and safe industrial workspace, ensuring regulatory compliance and operator health. Supplied in India by United Spectrum Instruments, authorised Donaldson BOFA distributor.
Discover More
Icon6

Industrial Laser Systems

Industrial Laser Systems delivers high-precision, reliable laser performance for marking, cutting, welding, micro-machining, and advanced manufacturing applications across diverse industrial.
Discover More
Icon9

Optical Communication Test & Measurement

Optical Communication Systems integrate optical transmitters, receivers, lasers, and OSA for signal generation, transmission.
Discover More
Icon8

Optical Sensors, IR Emitters & LEDs

Optical UV Sensors, IR Emitters and LEDs provide precise ultraviolet detection and measurement for monitoring, analysis, safety, and scientific applications across industrial and research environments.
Discover More
Icon6

Opto-Electronic Packaging Systems

Opto-electronic packaging systems enable precise assembly, alignment, and packaging of opto-electronic devices for production.
Discover More