UV Arc Sensing in Electrified Railways

Key Highlights
- Arc detection at the pantograph and contact wire for electrified railways, from line acceptance tests to onboard monitoring
- Solar-blind SiC photodiode responding only from 200 to 280 nm, so daylight does not trigger it on open track
- Response time under 1 µs to capture short arcs, with operation from −55 to +170 °C
- Matching sglux amplifiers with 0–10 V output and up to 100 kHz bandwidth, plus a UV reference set for lab checks
- Supplied and supported in India by USI, authorised distributor of sglux (Germany)
Why Electrified Railways Need to See Arcing
Electrified railways deliver traction power through a sliding contact between the pantograph and the overhead contact wire, or between a collector shoe and a conductor rail. Whenever that contact is briefly lost, through wire irregularities, wear, ice, speed or pantograph bounce, current jumps the gap as an electric arc.
Each arc burns the contact strip and the wire, adds electrical noise and is a sign that current collection is not as good as it should be. Arcing is therefore one of the measures used when new lines, new pantographs and new rolling stock are tested, and a rising arc count in service points to wear or misalignment long before a failure. The problem is measuring it reliably from a moving train, in daylight, at line speed.
UV Arc Sensing with a Solar-Blind SiC Photodiode
An electric arc emits strongly in the ultraviolet, including the deep UV-C band. UV arc sensing uses that emission: a sensor that responds only to UV-C sees the arc and ignores almost everything else around the track.
The sglux UV Arc sensor uses a silicon carbide (SiC) photodiode with a spectral response from 200 to 280 nm and a peak at 260 nm. Sunlight in this band is absorbed by the atmosphere before it reaches the ground, so the sensor stays dark in bright daylight and responds to the arc itself.
Why Solar Blindness and Speed Matter Most
For railway use, three properties of the detector decide whether arc counts can be trusted:
- Solar blindness: visible blindness better than 1010 means sunlight, reflections and visible lamps do not register as arcs, on open track or at tunnel portals.
- Response time: a response under 1 µs captures short arcs at line speed, so both the number and the duration of arcs can be recorded.
- Low dark current: a dark current of 0.2 fA keeps the baseline quiet, so weak arcs stand out clearly from the signal floor.
Built for Rolling Stock and Line Testing
The sensor is a component designed to be built into a detector head or a test system, close to the pantograph or collector.
Temperature and environment
The UV Arc sensor operates from −55 to +170 °C in a hermetic TO-46 metal can, with an EMI-resistant package suited to high-voltage traction surroundings.
Signal conditioning near the sensor
The AMPCON transimpedance amplifier converts the photodiode current into a 0–10 V signal with selectable gain from 105 to 1010 V/A and bandwidth up to 100 kHz, in a shielded aluminium housing.
Two pantographs, one amplifier
The Photodiode Amplifier Dual has two independent inputs with 0–10 V output per channel, so leading and trailing pantographs, or two viewing angles, can be monitored together.
Checking sensors in the lab
The UV-Arc Validation Set provides a stabilised UV source from 200 to 400 nm with a NIST/PTB-calibrated reference detector, for checking the response of UV sensors and measurement heads between campaigns.
Building a Complete Arc Detection Setup
A typical setup starts with the UV Arc sensor, mounted in a detector head facing the pantograph and contact wire. Its signal goes to an AMPCON transducer, which delivers a 0–10 V output to the data acquisition system or PLC. Where two pantographs or two viewing positions are monitored, the Photodiode Amplifier Dual handles both channels in one housing. Between test campaigns, the UV-Arc Validation Set lets the team check sensor response against a calibrated UV reference in the lab.
Who Uses It
- Rolling stock and locomotive manufacturers
- Pantograph and current-collection equipment makers
- Railway testing, research and standards organisations
- Metro rail operators and overhead equipment contractors
- Universities and institutes researching railway power systems
Supply and Support in India
United Spectrum Instruments (USI), Chennai, is the authorised distributor of sglux (Germany) in India and supplies UV arc sensing components, from UV arc sensors and photodiode amplifiers to UV calibration equipment, for electrified railways, rolling stock and test system builders.
USI helps choose the sensor and amplifier combination for your detector design and provides integration guidance, calibration and after-sales support.
Request a Configuration
Download the brochure from this page, use the Enquire Now button, write to sales@unitedspectrum.in, or call +91 93631 83748 / +91 97899 04948. Please mention:
- The application: line or pantograph acceptance testing, onboard monitoring or research
- The traction system (AC overhead line, DC overhead line or conductor rail) and train speed
- Number of measuring points or pantographs to be monitored
- Your data acquisition system or PLC input, and whether lab calibration equipment is also needed
GET IN TOUCH WITH US
Have a Project in Mind ? Let’s Talk
FAQs
Why is arcing measured on electrified railways?
On electrified railways, an arc forms whenever the pantograph or collector shoe briefly loses contact with the overhead wire or conductor rail. Each arc burns the contact strip and the wire and adds electrical noise. Counting arcs and their duration shows how well current collection works, so arcing is measured when new lines, pantographs and trains are tested, and a rising arc rate in service points to wear.
How does a UV arc sensor ignore sunlight?
The sglux UV Arc sensor uses a silicon carbide photodiode that responds only from 200 to 280 nm, the deep UV-C band. Sunlight in this band is absorbed by the atmosphere before it reaches the ground, and the sensor’s visible blindness is better than 10¹⁰. Daylight, reflections and visible lamps therefore do not register, while the UV-C emitted by an electric arc does.
How fast does UV arc sensing need to be on a moving train?
Arcs between pantograph and contact wire can be very short, especially at line speed, so the detector must react faster than the arc lasts. The UV Arc sensor responds in under 1 µs, and the AMPCON transducer passes the signal with bandwidth up to 100 kHz. Together they let a data acquisition system record both the number of arcs and how long each one lasts.
Who supplies UV arc sensing for electrified railways in India?
United Spectrum Instruments (USI), Chennai, is the authorised distributor of sglux (Germany) in India. USI supplies the UV Arc sensor, AMPCON and dual photodiode amplifiers and the UV-Arc Validation Set to rolling stock makers, pantograph manufacturers, test organisations and research groups, as a complete setup from one supplier with integration guidance, calibration and after-sales support.
How do I get a quote or datasheet for UV arc sensing?
Download the brochure from this page or click Enquire Now. You can also email sales@unitedspectrum.in or call +91 93631 83748 / +91 97899 04948. For an accurate quote, mention whether the setup is for line testing, onboard monitoring or research, the traction system and train speed, the number of measuring points and your data acquisition system or PLC input.